Precision of a joint constrained stratified allocation
Source:R/prec_alloc_joint.R
prec_alloc_joint.RdEvaluate achieved precision for every indicator and domain requirement under
a stratum allocation, or check a fitted n_alloc_joint() plan.
Usage
prec_alloc_joint(frame, ...)
# Default S3 method
prec_alloc_joint(
frame,
n = NULL,
measures = NULL,
...,
targets = NULL,
objective = NULL,
budget = NULL,
psu = NULL,
certainty_cutoff = NULL,
n_psu_per_zone = NULL,
unit_cost = NULL,
alpha = 0.05,
deff = 1,
resp_rate = 1,
eligibility_rate = 1,
eligible_per_unit = 1,
df = NULL,
min_n_stratum = NULL,
fpc = c("unit", "stage", "none"),
plan = NULL
)
# S3 method for class 'svyplan_alloc_joint'
prec_alloc_joint(frame, ...)Arguments
- frame
For the default method, a stratum-level data frame as in
n_alloc_joint(). Forsvyplan_alloc_jointobjects, an allocation fromn_alloc_joint().- ...
Additional arguments passed to methods. Unused arguments are rejected.
- n
Numeric vector of stratum sample sizes (ultimate units) of length
nrow(frame). Required with a raw frame. For a cluster frame, the supplied sizes must imply whole PSU counts at the specified takes. See Details for the defaults when passing an allocation.- measures
Long data frame of per-stratum indicator statistics, as in
n_alloc_joint().- targets
Optional precision targets data frame, as in
n_alloc_joint().- objective
Optional objective specification, as in
n_alloc_joint().- budget
Optional budget used with
objectiveto compute budget residual.- psu
Optional PSU register, as in
n_alloc_joint().- certainty_cutoff
Optional certainty probability cutoff, as in
n_alloc_joint().- n_psu_per_zone
Optional
1or2PSUs per zone, as inn_alloc_joint().- unit_cost
Optional scalar or length-
nrow(frame)per-unit cost.- alpha
Significance level, default
0.05.- deff
Default design effect multiplier (
> 0).- resp_rate
Default expected response rate in
(0, 1].- eligibility_rate
Default share of issued units in scope in
(0, 1].- eligible_per_unit
Default eligible units per sampled unit (
> 0). Available for designs without a PSU register. As inn_alloc_joint(), any of these four other than 1 is refused when every row a target or the objective uses takes the value from ameasuresorframecolumn, since the argument would be ignored.- df
Optional degrees of freedom for MOE and RMOE targets.
- min_n_stratum
Optional minimum sample size per stratum.
- fpc
Finite population correction (
"unit","stage", or"none"). Leave the default for a PSU register.- plan
Optional
svyplan()object providing design defaults.
Value
A svyplan_prec object with type = "alloc_joint", per-constraint
results in $detail, stratum bound checks in $bounds, and optional
$objective, $objective_value, and $psu.
Details
For an element or cluster fit,
prec_alloc_joint(fit)assesses the continuous design. Supplyn = fit$detail$n_intto assess its whole counts. A free-take fit uses its stored whole takes with explicitn.For a register fit,
prec_alloc_joint(fit)assesses the stored whole field design, including its certainty split, remainder draw, and per-PSU takes. Supplyingn,frame,psu,certainty_cutoff, orn_psu_per_zonereconstructs the assessment. A rawframewithpsuneeds explicit totals and a fixedtake_2in the frame.
Pass an assessment to predict.svyplan() to vary assumptions such as
response, variance, or cost. Leave n out of the scenario grid to hold the
allocation fixed. See vignette("joint-allocation") for worked designs.
See also
n_alloc_joint() to reoptimize an assessment, design_df() for
the field design's degrees of freedom, and prec_alloc() for
classic single-indicator allocation precision.
Other stratified design functions:
merge_psus(),
n_alloc(),
n_alloc_joint(),
prec_alloc(),
strata_bound()
Examples
frame <- data.frame(
stratum = c("North urban", "North rural", "South urban"),
region = c("North", "North", "South"),
N = c(1000, 1800, 1200)
)
measures <- data.frame(
stratum = rep(frame$stratum, 2),
name = rep(c("coverage", "income"), each = 3),
p = c(0.5, 0.4, 0.6, NA, NA, NA),
mean = c(NA, NA, NA, 50, 55, 60),
sd = c(NA, NA, NA, 10, 12, 15)
)
targets <- data.frame(
name = c("coverage", "income"),
domain = c(".overall", "region"),
level = c(NA, "North"),
cv = c(0.06, NA),
moe = c(NA, 3)
)
fit <- n_alloc_joint(frame, measures, targets = targets)
prec_alloc_joint(fit)
#> Joint allocation precision (2 constraints)
#> targets: all pass
#> showing 1 binding of 2
#>
#> constraint .metric .target .achieved .pass
#> coverage@.overall:cv cv 0.06 0.06 TRUE
#>
#> ... see $detail for all rows
prec_alloc_joint(fit, n = fit$detail$n_int)
#> Joint allocation precision (2 constraints)
#> targets: all pass
# Assess the fixed-take field design at two response rates
cluster <- data.frame(
stratum = "A", N = 100000, N_1 = 100, take_2 = 10, cost_1 = 50, cost_2 = 1
)
measure <- data.frame(stratum = "A", name = "coverage", p = 0.5, icc_1 = 0.05)
goal <- data.frame(name = "coverage", cv = 0.08)
cluster_fit <- n_alloc_joint(cluster, measure, targets = goal)
assessment <- prec_alloc_joint(cluster_fit, n = cluster_fit$detail$n_int)
predict(assessment, data.frame(resp_rate = c(1, 0.8)))
#> resp_rate n cost .max_ratio .n_fail .feasible
#> 1 1.0 230 1380 0.991357 0 TRUE
#> 2 0.8 230 1380 1.069715 1 FALSE